{"id":1091,"date":"2025-04-15T13:46:15","date_gmt":"2025-04-15T05:46:15","guid":{"rendered":"http:\/\/mate-solar.com\/?p=1091"},"modified":"2025-11-25T17:36:26","modified_gmt":"2025-11-25T09:36:26","slug":"armario-exterior-de-alta-tension-ess-all-in-one-60kwh-alto-grado-de-integracion","status":"publish","type":"post","link":"https:\/\/www.mate-solar.com\/es\/outdoor-high-voltage-cabinet-ess-all-in-one-60kwh-high-degree-of-integration\/","title":{"rendered":"Armario exterior de alto voltaje ESS todo en uno de 60 kWh para una instalaci\u00f3n sencilla"},"content":{"rendered":"<p class=\"has-black-color has-white-background-color has-text-color has-background has-link-color wp-elements-18bc78fc6f4e68213880307499cd044a wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"has-text-align-center has-black-color has-white-background-color has-text-color has-background has-link-color wp-elements-8b937bf05aa29e8f12b734229637ec52 wp-block-paragraph\" style=\"font-size:32px\"><strong>Expansi\u00f3n en el lado CA<\/strong><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img decoding=\"async\" width=\"1024\" height=\"614\" src=\"http:\/\/mate-solar.com\/wp-content\/uploads\/2025\/04\/Unified-outdoor-ESS-for-60kWh-solar-storage-with-integrated-design-1024x614.webp\" alt=\"\" class=\"wp-image-1099\" srcset=\"https:\/\/www.mate-solar.com\/wp-content\/uploads\/2025\/04\/Unified-outdoor-ESS-for-60kWh-solar-storage-with-integrated-design-1024x614.webp 1024w, https:\/\/www.mate-solar.com\/wp-content\/uploads\/2025\/04\/Unified-outdoor-ESS-for-60kWh-solar-storage-with-integrated-design-300x180.webp 300w, https:\/\/www.mate-solar.com\/wp-content\/uploads\/2025\/04\/Unified-outdoor-ESS-for-60kWh-solar-storage-with-integrated-design-768x461.webp 768w, https:\/\/www.mate-solar.com\/wp-content\/uploads\/2025\/04\/Unified-outdoor-ESS-for-60kWh-solar-storage-with-integrated-design.webp 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"has-text-align-center has-black-color has-white-background-color has-text-color has-background has-link-color wp-elements-9cbb5cc604b51756952e58f6f24fcb3f wp-block-paragraph\" style=\"font-size:32px\"><strong>Informaci\u00f3n sobre el producto<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table aligncenter has-medium-font-size\"><table class=\"has-black-color has-white-background-color has-text-color has-background has-link-color\"><tbody><tr><td><strong><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-luminous-vivid-orange-color\">M\u00f3dulo<\/mark><\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>MTBK 3060<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>MTBK 5060<\/strong><\/td><\/tr><tr><td><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-luminous-vivid-orange-color\">Par\u00e1metros de la bater\u00eda<\/mark><\/td><td class=\"has-text-align-center\" data-align=\"center\"><\/td><td class=\"has-text-align-center\" data-align=\"center\"><\/td><\/tr><tr><td>N\u00famero de bater\u00edas<\/td><td class=\"has-text-align-center\" data-align=\"center\">12V<\/td><td class=\"has-text-align-center\" data-align=\"center\">12V<\/td><\/tr><tr><td>Tensi\u00f3n nominal<\/td><td class=\"has-text-align-center\" data-align=\"center\">614.4V<\/td><td class=\"has-text-align-center\" data-align=\"center\">614.4V<\/td><\/tr><tr><td>Rango de tensi\u00f3n<\/td><td class=\"has-text-align-center\" data-align=\"center\">537.5~691.2V<\/td><td class=\"has-text-align-center\" data-align=\"center\">537.5~691.2V<\/td><\/tr><tr><td>Energ\u00eda nominal<\/td><td class=\"has-text-align-center\" data-align=\"center\">60 kWh<\/td><td class=\"has-text-align-center\" data-align=\"center\">60 kWh<\/td><\/tr><tr><td>Corriente m\u00e1x. de carga y descarga<\/td><td class=\"has-text-align-center\" data-align=\"center\">100A<\/td><td class=\"has-text-align-center\" data-align=\"center\">100A<\/td><\/tr><tr><td>Comunicaci\u00f3n<\/td><td class=\"has-text-align-center\" data-align=\"center\">RS485\/CAN<\/td><td class=\"has-text-align-center\" data-align=\"center\">RS485\/CAN<\/td><\/tr><tr><td>Ciclo de vida<\/td><td class=\"has-text-align-center\" data-align=\"center\">6000veces<\/td><td class=\"has-text-align-center\" data-align=\"center\">6000veces<\/td><\/tr><tr><td><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-luminous-vivid-orange-color\">Par\u00e1metros fotovoltaicos<\/mark><\/td><td class=\"has-text-align-center\" data-align=\"center\"><\/td><td class=\"has-text-align-center\" data-align=\"center\"><\/td><\/tr><tr><td>Potencia de entrada FV m\u00e1x.<\/td><td class=\"has-text-align-center\" data-align=\"center\">39 kW<\/td><td class=\"has-text-align-center\" data-align=\"center\">65 kW<\/td><\/tr><tr><td>Tensi\u00f3n nominal de entrada<\/td><td class=\"has-text-align-center\" data-align=\"center\">600 Vcc<\/td><td class=\"has-text-align-center\" data-align=\"center\">600 Vcc<\/td><\/tr><tr><td>Tensi\u00f3n de entrada m\u00e1x.<\/td><td class=\"has-text-align-center\" data-align=\"center\">1000Vcc<\/td><td class=\"has-text-align-center\" data-align=\"center\">1000Vcc<\/td><\/tr><tr><td>Rango de tensi\u00f3n MPPT<\/td><td class=\"has-text-align-center\" data-align=\"center\">200~850Vcc<\/td><td class=\"has-text-align-center\" data-align=\"center\">200~850Vcc<\/td><\/tr><tr><td>Corriente de entrada FV<\/td><td class=\"has-text-align-center\" data-align=\"center\">36+36+36(A)<\/td><td class=\"has-text-align-center\" data-align=\"center\">36+36+36+36(A)<\/td><\/tr><tr><td><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-luminous-vivid-orange-color\">Par\u00e1metros del lado de CA<\/mark><\/td><td class=\"has-text-align-center\" data-align=\"center\"><\/td><td class=\"has-text-align-center\" data-align=\"center\"><\/td><\/tr><tr><td>Potencia nominal de entrada\/salida de CA<\/td><td class=\"has-text-align-center\" data-align=\"center\">30kVA<\/td><td class=\"has-text-align-center\" data-align=\"center\">50kVA<\/td><\/tr><tr><td>CA Potencia m\u00e1x. de entrada\/salida<\/td><td class=\"has-text-align-center\" data-align=\"center\">33kVA<\/td><td class=\"has-text-align-center\" data-align=\"center\">55kVA<\/td><\/tr><tr><td>Corriente nominal de entrada\/salida CA<\/td><td class=\"has-text-align-center\" data-align=\"center\">45.6A<\/td><td class=\"has-text-align-center\" data-align=\"center\">75.8A<\/td><\/tr><tr><td>CA Potencia m\u00e1x. de entrada\/salida<\/td><td class=\"has-text-align-center\" data-align=\"center\">60A<\/td><td class=\"has-text-align-center\" data-align=\"center\">83.3A<\/td><\/tr><tr><td>Tensi\u00f3n<\/td><td class=\"has-text-align-center\" data-align=\"center\">3L\/N\/PE; 230\/400V<\/td><td class=\"has-text-align-center\" data-align=\"center\">3L\/N\/PE; 230\/400V<\/td><\/tr><tr><td>Frecuencia<\/td><td class=\"has-text-align-center\" data-align=\"center\">50\/60 Hz<\/td><td class=\"has-text-align-center\" data-align=\"center\">50\/60 Hz<\/td><\/tr><tr><td>THDi<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u22643%<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u22643%<\/td><\/tr><tr><td>Factor de potencia<\/td><td class=\"has-text-align-center\" data-align=\"center\">0,8 por delante y 0,8 por detr\u00e1s<\/td><td class=\"has-text-align-center\" data-align=\"center\">0,8 por delante y 0,8 por detr\u00e1s<\/td><\/tr><tr><td><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-luminous-vivid-orange-color\">Par\u00e1metros del sistema<\/mark><\/td><td class=\"has-text-align-center\" data-align=\"center\"><\/td><td class=\"has-text-align-center\" data-align=\"center\"><\/td><\/tr><tr><td>Dimensiones (An*Al*F)<\/td><td class=\"has-text-align-center\" data-align=\"center\">1200\u00d72160\u00d7750mm<\/td><td class=\"has-text-align-center\" data-align=\"center\">1200\u00d72160\u00d7750mm<\/td><\/tr><tr><td>Peso<\/td><td class=\"has-text-align-center\" data-align=\"center\">860 kg<\/td><td class=\"has-text-align-center\" data-align=\"center\">880 kg<\/td><\/tr><tr><td>Comunicaci\u00f3n<\/td><td class=\"has-text-align-center\" data-align=\"center\">CAN\/RS485\/WiFi\/ETH<\/td><td class=\"has-text-align-center\" data-align=\"center\">CAN\/RS485\/WiFi\/ETH<\/td><\/tr><tr><td>Garant\u00eda<\/td><td class=\"has-text-align-center\" data-align=\"center\">5 a\u00f1os<\/td><td class=\"has-text-align-center\" data-align=\"center\">5 a\u00f1os<\/td><\/tr><tr><td>Grado de protecci\u00f3n de la caja<\/td><td class=\"has-text-align-center\" data-align=\"center\">IP55<\/td><td class=\"has-text-align-center\" data-align=\"center\">IP55<\/td><\/tr><tr><td>Refrigeraci\u00f3n<\/td><td class=\"has-text-align-center\" data-align=\"center\">Refrigeraci\u00f3n por aire<\/td><td class=\"has-text-align-center\" data-align=\"center\">Refrigeraci\u00f3n por aire<\/td><\/tr><tr><td>Temperatura ambiente<\/td><td class=\"has-text-align-center\" data-align=\"center\">-30~50\u00b0C<\/td><td class=\"has-text-align-center\" data-align=\"center\">-30~50\u00b0C<\/td><\/tr><tr><td>Humedad<\/td><td class=\"has-text-align-center\" data-align=\"center\">10%~95%RH<\/td><td class=\"has-text-align-center\" data-align=\"center\">10%~95%RH<\/td><\/tr><tr><td>Altitud<\/td><td class=\"has-text-align-center\" data-align=\"center\">&lt;2000m<\/td><td class=\"has-text-align-center\" data-align=\"center\">&lt;2000m<\/td><\/tr><tr><td>Certificaciones<\/td><td class=\"has-text-align-center\" data-align=\"center\">UN38.3\/CE\/IEC62619\/VDE-AR-N 4105\/IEC 62109<\/td><td class=\"has-text-align-center\" data-align=\"center\">UN38.3\/CE\/IEC62619\/VDE-AR-N 4105\/IEC 62109<\/td><\/tr><\/tbody><\/table><\/figure>","protected":false},"excerpt":{"rendered":"<p>Expansion in AC side Product Information Module MTBK 3060 MTBK 5060 Battery parameters Number of battery packs 12V 12V Rated voltage 614.4V 614.4V Voltage range 537.5~691.2V 537.5~691.2V Rated energy 60kWh 60kWh Max. charging &amp; discharging current 100A 100A Communication RS485\/CAN RS485\/CAN Cycle life 6000times 6000times PV parameters Max.PV input power 39kW 65kW Rated input voltage [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"categories":[26],"tags":[],"class_list":["post-1091","post","type-post","status-publish","format-standard","hentry","category-ess-energy-storage"],"_links":{"self":[{"href":"https:\/\/www.mate-solar.com\/es\/wp-json\/wp\/v2\/posts\/1091","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mate-solar.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.mate-solar.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.mate-solar.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mate-solar.com\/es\/wp-json\/wp\/v2\/comments?post=1091"}],"version-history":[{"count":8,"href":"https:\/\/www.mate-solar.com\/es\/wp-json\/wp\/v2\/posts\/1091\/revisions"}],"predecessor-version":[{"id":2432,"href":"https:\/\/www.mate-solar.com\/es\/wp-json\/wp\/v2\/posts\/1091\/revisions\/2432"}],"wp:attachment":[{"href":"https:\/\/www.mate-solar.com\/es\/wp-json\/wp\/v2\/media?parent=1091"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.mate-solar.com\/es\/wp-json\/wp\/v2\/categories?post=1091"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.mate-solar.com\/es\/wp-json\/wp\/v2\/tags?post=1091"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}