{"id":779,"date":"2025-04-02T17:00:23","date_gmt":"2025-04-02T09:00:23","guid":{"rendered":"http:\/\/mate-solar.com\/?p=779"},"modified":"2025-11-14T13:42:41","modified_gmt":"2025-11-14T05:42:41","slug":"20kw-netzgekoppeltes-solarenergiesystem-fur-den-hausgebrauch-zu-einem-fairen-preis-kaufen","status":"publish","type":"post","link":"https:\/\/www.mate-solar.com\/de\/buy-20kw-on-grid-solar-energy-system-for-home-use-at-fair-price\/","title":{"rendered":"Kaufen Sie 20KW On Grid Solar Energy System f\u00fcr den Heimgebrauch zu einem fairen Preis"},"content":{"rendered":"<p class=\"has-black-color has-white-background-color has-text-color has-background has-link-color wp-elements-18bc78fc6f4e68213880307499cd044a\"><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img decoding=\"async\" width=\"1024\" height=\"614\" src=\"http:\/\/mate-solar.com\/wp-content\/uploads\/2025\/04\/20KW-three-phase-on-grid-solar-system-for-residential-energy-needs-1024x614.webp\" alt=\"\" class=\"wp-image-817\" srcset=\"https:\/\/www.mate-solar.com\/wp-content\/uploads\/2025\/04\/20KW-three-phase-on-grid-solar-system-for-residential-energy-needs-1024x614.webp 1024w, https:\/\/www.mate-solar.com\/wp-content\/uploads\/2025\/04\/20KW-three-phase-on-grid-solar-system-for-residential-energy-needs-300x180.webp 300w, https:\/\/www.mate-solar.com\/wp-content\/uploads\/2025\/04\/20KW-three-phase-on-grid-solar-system-for-residential-energy-needs-768x461.webp 768w, https:\/\/www.mate-solar.com\/wp-content\/uploads\/2025\/04\/20KW-three-phase-on-grid-solar-system-for-residential-energy-needs.webp 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"has-text-align-center has-black-color has-white-background-color has-text-color has-background has-link-color wp-elements-9cbb5cc604b51756952e58f6f24fcb3f\" style=\"font-size:32px\"><strong>Informationen zum Produkt<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table has-medium-font-size\"><table class=\"has-black-color has-white-background-color has-text-color has-background has-link-color\"><tbody><tr><td><strong><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-luminous-vivid-orange-color\">PV-Module<\/mark><\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><\/td><\/tr><tr><td><strong>Parameter<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><\/td><\/tr><tr><td>Testbedingungen<\/td><td class=\"has-text-align-center\" data-align=\"center\">STC<\/td><\/tr><tr><td>Maximale Leistung (Pmax\/W)<\/td><td class=\"has-text-align-center\" data-align=\"center\">440W<\/td><\/tr><tr><td>Leerlaufspannung (Voc\/V)<\/td><td class=\"has-text-align-center\" data-align=\"center\">39.44<\/td><\/tr><tr><td>Kurzschlussstrom (lsc\/A)<\/td><td class=\"has-text-align-center\" data-align=\"center\">14.27<\/td><\/tr><tr><td>Spannung bei maximaler Leistung (Vmp\/V)<\/td><td class=\"has-text-align-center\" data-align=\"center\">32.45<\/td><\/tr><tr><td>Strom bei maximaler Leistung (lmp\/A)<\/td><td class=\"has-text-align-center\" data-align=\"center\">13.56<\/td><\/tr><tr><td>Wirkungsgrad des Moduls (%)<\/td><td class=\"has-text-align-center\" data-align=\"center\">22.53<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"has-black-color has-white-background-color has-text-color has-background has-link-color wp-elements-46e4810814ddd9a1b2a027417057e0d4\">Garantiert positive Leistungstoleranz (0~+5W); Geringerer Widerstandsverlust bei niedrigerem Betriebsstrom; H\u00f6here Energieausbeute bei niedrigerem Betriebsstrom; Geringeres Hot-Spot-Risiko durch optimiertes elektrisches Design und niedrigeren Betriebsstrom.<\/p>\n\n\n\n<p class=\"has-black-color has-white-background-color has-text-color has-background has-link-color wp-elements-18bc78fc6f4e68213880307499cd044a\"><\/p>\n\n\n\n<figure class=\"wp-block-table has-medium-font-size\"><table class=\"has-black-color has-white-background-color has-text-color has-background has-link-color\"><tbody><tr><td><strong><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-luminous-vivid-orange-color\">Wechselrichter<\/mark><\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><\/td><\/tr><tr><td><strong>Parameter<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><\/td><\/tr><tr><td><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-luminous-vivid-orange-color\">Eingangsdaten (DC)<\/mark><\/td><td class=\"has-text-align-center\" data-align=\"center\"><\/td><\/tr><tr><td>Max. empfohlene PV-Leistung<\/td><td class=\"has-text-align-center\" data-align=\"center\">30000W<\/td><\/tr><tr><td>MPPT-Spannungsbereich<\/td><td class=\"has-text-align-center\" data-align=\"center\">200V-1000V<\/td><\/tr><tr><td>Anzahl der MPP-Tracker<\/td><td class=\"has-text-align-center\" data-align=\"center\">3<\/td><\/tr><tr><td>Anzahl der PV-Strings pro MPP-Tracker<\/td><td class=\"has-text-align-center\" data-align=\"center\">4\/4\/4<\/td><\/tr><tr><td><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-luminous-vivid-orange-color\">Ausgangsdaten (AC)<\/mark><\/td><td class=\"has-text-align-center\" data-align=\"center\"><\/td><\/tr><tr><td>AC-Nennleistung<\/td><td class=\"has-text-align-center\" data-align=\"center\">20000W<\/td><\/tr><tr><td>AC-Nennspannung (Bereich*)<\/td><td class=\"has-text-align-center\" data-align=\"center\">127V\/220V dreiphasig<\/td><\/tr><tr><td>AC-Netzfrequenz (Bereich*)<\/td><td class=\"has-text-align-center\" data-align=\"center\">50\/60 Hz(45-55Hz\/55-65 Hz)<\/td><\/tr><tr><td><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-luminous-vivid-orange-color\">Allgemeine Daten<\/mark><\/td><td class=\"has-text-align-center\" data-align=\"center\"><\/td><\/tr><tr><td>Abmessungen (B\/H\/T)<\/td><td class=\"has-text-align-center\" data-align=\"center\">680\/508\/281mm<\/td><\/tr><tr><td>Gewicht<\/td><td class=\"has-text-align-center\" data-align=\"center\">52kg<\/td><\/tr><tr><td>Topologie<\/td><td class=\"has-text-align-center\" data-align=\"center\">Transformatorlos<\/td><\/tr><tr><td>K\u00fchlung<\/td><td class=\"has-text-align-center\" data-align=\"center\">Nat\u00fcrliche Konvektion<\/td><\/tr><tr><td>Schutzgrad<\/td><td class=\"has-text-align-center\" data-align=\"center\">IP65<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"has-black-color has-white-background-color has-text-color has-background has-link-color wp-elements-2893d98f2344576508e4ee29845cbd43\">220V Dreiphasenl\u00f6sung; hoher Wirkungsgrad bis zu 98,8%; lokale WiFi-Konfiguration; AC&amp;DC Typ II SPD.<\/p>","protected":false},"excerpt":{"rendered":"<p>Product Information PV Modules Parameter Testing Condition STC Maximum Power(Pmax\/W) 440W Open Circuit Voltage(Voc\/V) 39.44 Short Circuit Current(lsc\/A) 14.27 Voltage at Maximum Power(Vmp\/V) 32.45 Current at Maximum Power(lmp\/A) 13.56 Module Efficiency(%) 22.53 Positive power tolerance (0~+5W) guaranteed; Reduced resistive loss with lower operating current; Higher energy yield with lower operating current; Reduced hot spot risk [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"categories":[20],"tags":[],"class_list":["post-779","post","type-post","status-publish","format-standard","hentry","category-residential-energy-storage-system"],"_links":{"self":[{"href":"https:\/\/www.mate-solar.com\/de\/wp-json\/wp\/v2\/posts\/779","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mate-solar.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.mate-solar.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.mate-solar.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mate-solar.com\/de\/wp-json\/wp\/v2\/comments?post=779"}],"version-history":[{"count":9,"href":"https:\/\/www.mate-solar.com\/de\/wp-json\/wp\/v2\/posts\/779\/revisions"}],"predecessor-version":[{"id":2472,"href":"https:\/\/www.mate-solar.com\/de\/wp-json\/wp\/v2\/posts\/779\/revisions\/2472"}],"wp:attachment":[{"href":"https:\/\/www.mate-solar.com\/de\/wp-json\/wp\/v2\/media?parent=779"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.mate-solar.com\/de\/wp-json\/wp\/v2\/categories?post=779"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.mate-solar.com\/de\/wp-json\/wp\/v2\/tags?post=779"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}